- Home
- Products
- INSULATION FOIL
- Radiant Barrier (MS2095) CIDB SIRIM BOMBA (CLASS 0)
Radiant Barrier / Reflective Insulation / Vapor Barrier are known to be premium quality and is extensive used in various industries like Construction, Packaging and etc.
They can be used as wrapping material for HVAC Ducting, Roofing, Wall, Floor, and etc
They can be used as wrapping material for HVAC Ducting, Roofing, Wall, Floor, and etc
MS2095 is standard compliance according to the Department of Standards Malaysia
Declaration of standard that have been announce on October 2014 is referring to the building materials that comply with radiant barrier and reflective insulation building materials specification.
This standard also listed under fourth schedule of standard for certification construction material by Construction Industry Development Board (CIDB) Malaysia
Declaration of standard that have been announce on October 2014 is referring to the building materials that comply with radiant barrier and reflective insulation building materials specification.
This standard also listed under fourth schedule of standard for certification construction material by Construction Industry Development Board (CIDB) Malaysia
BS476 Part 6 : Fire Propagation Test
This measure the amount of heat released when the product under test is burned
BS476 Part 7: Surface Spread of Flame Test
Method of test to determine the classification of the surface spread of flame of products. Class 1 is the best rating
To achieve Class “0” a product must achieve Class 1 in the Part 7 test and also past Part 6 test.
Test done under this group of product is ISO 8301, MS ISO08302; ASTM C 1371; AS/NZS 4201.1; AS/NZS 4201.3; AS/NZS 1301.448s; AS/NZS 1301.423rp, TAPPI T470 and ASTM D1004
This measure the amount of heat released when the product under test is burned
BS476 Part 7: Surface Spread of Flame Test
Method of test to determine the classification of the surface spread of flame of products. Class 1 is the best rating
To achieve Class “0” a product must achieve Class 1 in the Part 7 test and also past Part 6 test.
Test done under this group of product is ISO 8301, MS ISO08302; ASTM C 1371; AS/NZS 4201.1; AS/NZS 4201.3; AS/NZS 1301.448s; AS/NZS 1301.423rp, TAPPI T470 and ASTM D1004
99% Pure Aluminum Foil with high reflectivity (>0.98) and low emissivity (<0.02) surface
Comply with fire properties according to the standard BS476 Part 6 & 7
Reinforced with high quality woven fabric or bidirectional fiberglass scrim for better tearing resistance, higher tensile strength and assist on mechanical strength.
Special bonding layer combined with aluminum foil giving it superior Vapor Barrier and Fire Retardant properties
Suggested size:
Comply with fire properties according to the standard BS476 Part 6 & 7
Reinforced with high quality woven fabric or bidirectional fiberglass scrim for better tearing resistance, higher tensile strength and assist on mechanical strength.
Special bonding layer combined with aluminum foil giving it superior Vapor Barrier and Fire Retardant properties
Suggested size:
Product | Width (m) | Length (m) | Optimum pallet packing |
MS APRA K731 MS APRA K431 MS APRA K531 MS APRA K831 |
1.25 ±1% | 60 ±1% | 100 Rolls |
MS AWA K750 | 1.25 ±1% | 60 ±1% | 110 Rolls |
MS AWA K750 | MS APRA K731 | MS APRA K431 | |
DESCRIPTION | Fire Retardant Double Sided Reflective Aluminum Woven Foil |
Fire Retardant Double Sided Reflective Aluminum Paper Foil, 8X8 Fiberglass Scrim Reinforced |
Fire Retardant Double Sided Reflective Aluminum Paper Foil, 16X8 Fiberglass Scrim Reinforced |
GRAMMAGE |
130 –150 gsm | 165 –220 gsm | 165 –220 gsm |
THICKNESS |
130 –180 microns | 230 –300 microns | 230 –300 microns |
THERMAL RESISTANCE (ISO 8301, MS ISO8302) |
~ 1.212 m²K/w | ~ 1.375 m²K/w | ~ 1.375 m²K/w |
REFLECTIVITY (ASTM C 1371) |
0.98 | 0.98 | 0.98 |
EMISSIVITY (ASTM C 1371) |
0.02 | 0.02 | 0.02 |
RESISTANCE TO DRY LAMINATION (AS/NZS 4201.1) |
No Delamination | No Delamination | No Delamination |
RESISTANCE TO WET LAMINATION (AS/NZS 4201.1) |
No Delamination | No Delamination | No Delamination |
SHRINKAGE (AS/NZS 4201.3) |
MD: < 0.5% CD: < 0.5% |
MD: < 0.5% CD: < 0.5% |
MD: < 0.5% CD: < 0.5% |
TENSILE STRENGTH (AS/NZS 1301.448s) |
MD: > 7.5 to < 9.5kN/m CD: > 7.5to < 9.5 kN/m |
MD: > 5 kN/m CD: > 3 kN/m |
MD: > 5 kN/m CD: > 3 kN/m |
EDGE TEAR RESISTANCE (TAPPI T470) |
MD: > 200 N CD: > 240 N |
MD: > 30 N CD: > 20 N |
MD: > 30 N CD: > 20 N |
VAPOUR BARRIER (ASTM E96) |
0.002 -0.14μg/N.s > 7 to < 450MN.s/g |
0.002 –0.14 μg/N.s | 0.002 –0.14 μg/N.s |
SURFACE WATER ABSORBENCY (AS/NZS 4201.6) |
- | > 100 g/m² | > 100 g/m² |
INITIAL TEAR RESISTANCE (ASTM D1004) |
MD: 45 –60 N CD: 45 –60 N |
- | - |
FOLDING ENDURANCE (AS/NZS 1301.423rp) |
- |
MD: > 2.00 log₁₀ 100 CD: > 1.70log₁₀ 50 |
MD: > 2.00 log₁₀ 100 CD: > 1.70 log₁₀ 50 |
LAYOUT DIAGRAM |
|
|
Heat insulation industrial material
HVAC duct insulation
Building wrapping
Cold room installation
Thermal tank
Wall insulation
Sauna room