Radiant Barrier / Reflective Insulation / Vapor Barrier are known to be premium quality and is extensive used in various industries like Construction, Packaging and etc.

They can be used as wrapping material for HVAC Ducting, Roofing, Wall, Floor, and etc
 


MS2095 is standard compliance according to the Department of Standards Malaysia
Declaration of standard that have been announce on October 2014 is referring to the building materials that comply with radiant barrier and reflective insulation building materials specification.
This standard also listed under fourth schedule of standard for certification construction material by  Construction Industry Development Board (CIDB) Malaysia
 



BS476 Part 6 : Fire Propagation Test
This measure the amount of heat released when the product under test is burned
BS476 Part 7: Surface Spread of Flame Test
Method of test to determine the classification of the surface spread of flame of products. Class 1 is the best rating
To achieve Class “0 a product must achieve Class 1 in the Part 7 test and also past Part 6 test.
Test done under this group of product is ISO 8301, MS ISO08302; ASTM C 1371; AS/NZS 4201.1; AS/NZS 4201.3; AS/NZS 1301.448s; AS/NZS 1301.423rp, TAPPI T470  and ASTM D1004
 


99% Pure Aluminum Foil with high reflectivity (>0.98) and low emissivity (<0.02) surface
Comply with fire properties according to the standard BS476 Part 6 & 7
Reinforced with  high quality woven fabric or bidirectional fiberglass scrim for better tearing resistance, higher tensile strength and assist on mechanical strength.
Special bonding layer combined with aluminum foil giving it superior Vapor Barrier and Fire Retardant properties
Suggested size:
 
 Product Width (m) Length (m) Optimum pallet packing
MS APRA K731
MS APRA K431
MS APRA K531
MS APRA K831
1.25 ±1% 60 ±1% 100 Rolls
MS AWA K750 1.25 ±1% 60 ±1% 110 Rolls
Customize size available upon request, subject to material availability & machine’s capacity




  MS AWA K750 MS APRA K731 MS APRA K431
DESCRIPTION Fire Retardant Double Sided Reflective Aluminum Woven Foil Fire Retardant Double Sided Reflective Aluminum Paper Foil, 8X8 Fiberglass Scrim Reinforced
 
Fire Retardant Double Sided Reflective Aluminum Paper Foil, 16X8 Fiberglass Scrim Reinforced
GRAMMAGE
 
130 –150 gsm 165 –220 gsm 165 –220 gsm
THICKNESS
 
130 –180 microns 230 –300 microns 230 –300 microns
THERMAL RESISTANCE
(ISO 8301, MS ISO8302)

 
~ 1.212 m²K/w ~ 1.375 m²K/w ~ 1.375 m²K/w
REFLECTIVITY
(ASTM C 1371)

 
0.98 0.98 0.98
EMISSIVITY
(ASTM C 1371)

 
0.02 0.02 0.02
RESISTANCE TO DRY LAMINATION
(AS/NZS 4201.1)

 
No Delamination No Delamination No Delamination
RESISTANCE TO WET LAMINATION
(AS/NZS 4201.1)

 
No Delamination No Delamination No Delamination
SHRINKAGE
(AS/NZS 4201.3)
MD: < 0.5%
CD: < 0.5%

 
MD: < 0.5%
CD: < 0.5%
MD: < 0.5%
CD: < 0.5%
TENSILE STRENGTH
(AS/NZS 1301.448s)
MD: > 7.5 to < 9.5kN/m
CD: > 7.5to < 9.5 kN/m

 
MD: > 5 kN/m
CD: > 3 kN/m
MD: > 5 kN/m
CD: > 3 kN/m
EDGE TEAR RESISTANCE
(TAPPI T470)
MD: > 200 N
CD: > 240 N

 
MD: > 30 N
CD: > 20 N
MD: > 30 N
CD: > 20 N
VAPOUR BARRIER
(ASTM E96)

 
0.002 -0.14μg/N.s
> 7 to < 450MN.s/g
0.002 –0.14 μg/N.s 0.002 –0.14 μg/N.s
SURFACE WATER ABSORBENCY
(AS/NZS 4201.6)

 
- > 100 g/m² > 100 g/m²
INITIAL TEAR  RESISTANCE
(ASTM D1004)

 
MD: 45 –60 N
CD: 45 –60 N
- -
FOLDING ENDURANCE
(AS/NZS 1301.423rp)
- MD: > 2.00 log₁₀ 100
CD: > 1.70log₁₀ 50
MD: > 2.00 log₁₀ 100
CD: > 1.70 log₁₀ 50

 
LAYOUT DIAGRAM  

 


Heat insulation industrial material
HVAC duct insulation
Building wrapping
Cold room installation
Thermal tank
Wall insulation
Sauna room 
    




 

MS AWA K750
MS AWA K750
MS APRA K731
MS APRA K731
MS APRA K431
MS APRA K431
Switch To Desktop Version